Solution for Issue: Elmaster Design Not Establishing Database Connection
Introduction
When AutoCAD runs with a borrowed license, a popup can disrupt initialization, affecting the Ides CAD-driver COM-server and causing the application to switch to standalone mode.
Problem definition
The popup that appears when the AutoCAD license is borrowed prevents proper initialization, causing the COM-server not to load in a timely manner, and the driver fails to connect to the database.
Solution
Run the MCSTARTUP command manually:
Once all components have loaded, open the command prompt in AutoCAD.
Execute MCSTARTUP to initiate the connection.
Preventive Measures
Manage AutoCAD licenses. Avoid borrowing licenses if possible.
Summary
To resolve the issue, manually run MCSTARTUP after AutoCAD/MasterDesign has fully loaded.
Check the license configuration and avoid borrowing licenses to prevent the problem.
https://imaster.se/wp-content/uploads/2020/06/logotype_ides_20-300x44.png00Johan Daleniushttps://imaster.se/wp-content/uploads/2020/06/logotype_ides_20-300x44.pngJohan Dalenius2024-10-25 15:27:252024-10-28 17:08:25Issue with database connection when using borrowed license i Autocad
Have you ever been sorting columns over and over in reverse order to in the end get the grid sorted by multiple columns? Occasionally one has a sorting and want to freeze the current sorting and apply a second subsorting.
Hold down Shift and click on the additional columns you want to sort, and they will be sorted in order from most significant, second, third and so on.
Objects ordered by Byggnadsplacering, Processfunktion.
This command can be used in grids and will perform the following actions. All fields/columns without any data are hidden. The width of shown fields is set to best fit, adjusted according to the widest data.
Example scenario: Empty cells marked with pink. Unless we were inspecting of those specific fields were empty or not the view give us little information. Are all fields to the right empty? Are all rows below empty?
Notice the size of the scroll bar. It is representative of how much data is shown out of the data loaded to the grid. When using the shortcut Ctrl+Shift+K the grid focuses on the non-empty cells.
https://imaster.se/wp-content/uploads/2020/06/logotype_ides_20-300x44.png00Johan Daleniushttps://imaster.se/wp-content/uploads/2020/06/logotype_ides_20-300x44.pngJohan Dalenius2024-02-22 10:00:002024-02-15 15:45:15Ctrl + Shift + K
When the process is being run with administrative privileges the user is unable to get Elmaster Design started properly.
Symptoms
Error messages at start of Design that says Failed to load Master Concept dlls and invalid class string.
Cause
To make it possible/easier to switch between parallel installed versions resources are registered during the initialization of the application. The registration is done for the user who is logged in.
If the application is run by another account – even if that account has high privileges – the part of the registry being used is not the same as where the references to the resources have been set up.
It is a limitation that the acad.exe process about to load Elmaster Design must be run by the logged in user.
Confirmation
To confirm if processes you initiate are being run by your logged on username one can often determine by opening a command prompt and looking at its title bar if it says administrator or not.
Another way to determine if you have this problem is by looking at the acad.exe process via Task Manager. Go to the information pane and select the columns to show via the context menu on the column headers. Choose to show elevated privileges. If your acad.exe process is running with elevated privileges that means it is being run as the administrator account.
Solution
If you are using the context menu on the icon and Run as Administrator – don’t.
Instead run in normal mode by clicking on the icon in start menu och double click on the desktop icon to start Elmaster Design.
Usually, this problem occurs when the user temporarily gains elevated privileges to install new software. Via policy or similar management, the processes initiated by the user are impersonated and run by the administrator account for the duration of the installation period. If that is the case, let whoever gave you the elevated privileges know when you are done. When impersonation ceases, the problem ceases.
Preventive measures
Avoid running the acad.exe processes as administrator. Run it as your logged on user.
If users are temporarily given local administrative privileges for installing software, it is advisable to plan ahead and schedule the installation at a time when the user is not supposed to be productive using Elmaster Design.
Hanteringen kring påminnelse om lånad licens har förändrats och ställer till bekymmer vid initieringen.
Förutsättningar (samtliga behöver vara uppfyllda)
Autocad 2020 eller nyare.
Autocad är konfigurerad med licensieringsmodell nätverkslicens.
Användaren har låntat en licens från licenspoolen.
Ritning öppnas från MasterExplorer.
Lösning
Ingen lösning tillgänglig. Ärende har upprättats till Autodesk.
Kringgå problemet
I nyare versioner pushar Autodesk för att man ska gå över till namngivna single-licenser via accounts.autodesk.com och används den licensmodellen undviks problemet.
Äldre versioner av Autocad 2018, 2019 fungerar problemfritt med lånad licens.
Vid användning av MasterExplorer är användaren vanligen uppkopplad direkt eller via vpn i företagets nätverk. Troligen behövs inte lån av licens för Autocad. Med kommandot RETURNLICENSE kan man återlämna en lånad nätverkslicens innan förfallodatum för lånet.
https://imaster.se/wp-content/uploads/2020/06/logotype_ides_20-300x44.png00Johan Daleniushttps://imaster.se/wp-content/uploads/2020/06/logotype_ides_20-300x44.pngJohan Dalenius2021-05-05 15:03:582024-04-08 08:34:27Problem vid lånad Autocad-licens
Följande beskrivning utgår från elMaster Design / Master Concept 20.0 tillsammans med BricsCAD v21.
Äldre mallar och symboler
Äldre mallar och symboler kan innehålla skräpdata som hanteras i Autocad men som ger problem när BricsCAD används. För att undvika att det ställer till problem finns det uppdaterade versioner av mallar och symboler att ladda ner.
Vid nyinstallation med installation av filserver kan dessa användas utan uppdatering.
Om det finns befintliga egna mallar och symboler som ska användas tillsammans med Bricscad öppna dessa dwg/dwt:er i Autocad och kör kommandot: AUDIT
Spara sedan mallen/symbolen så ska eventuella felaktigheter rättas till och det ska gå att använda tillsammans med BricCAD. Är det många mallar och symboler finns en färdig lisp som går att använda i Designs batchfunktion.
För nedladdningslänkar se längre ner.
elMaster Design tillsammans med BricsCAD
Genom att editera genvägen för elMaster Design går det att styra vilken cadmjukvara som ska starta, BricsCAD eller Autocad.
Som standard kommer Autocad alltid startas även om BricsCAD är installerad, är enbart BricsCAD installerad kommer den att startas direkt.
Är både Autocad och bricsCAD installerade går det bra att kopiera startikonen och skapa en för BricsCAD. Högerklicka på startikonen för elMaster Design och välj Egenskaper.
I rutan för Mål, lägg till en växel. /bricscad för att starta BricsCAD.
Master Concept tillsammans med BricsCAD
För att kunna öppna dwg-filer med BricsCAD från Master Explorer krävs det att det finns en dokumentstart som har BricsCAD som Applikation och Extern applikation. För Design-filer ska BricsCAD anges som Extern applikation och som Applikation ska resp Designstart anges. Se bild för exempel.
Role Modules – Read only removed
We have reworked and removed the use of “Read Only” modules. The read only modules replaced by “Read Access” modules and Edit.
Rework in the Data tab for objects
Article and Individual have moved out to own tabs, and some other smaller fixes to clear up the data for objects
Software Requirements changes client
Microsoft.Net Framework version 4.8
Oracle Client, Oracle Database 19c Client
Software Requirements changes server
Oracle version 18c XE
Oracle version 19c