Posts

Designation Configuration

In version 19.0 it is possible to control in more detail which settings you want. Not just by standard and main folder, but also by structure and part of plant. The different settings format, category structure and letter codes have their own dialogs where you create the different configurations. In the new designation configuration dialog, you choose which configurations should apply to which structures.

DesConfig

Designation Format

In version 19.0 we have improved the possibility to configure the object designations in the system. You can now in detail control what designations are allowed for each level and designation structure.

For each level of the designation you can specify a mask that controls what is a permitted designation and what prefix is ​​to be used before the level (or none). The mask is described with a simplified syntax A for letters and n for numbers. If needed, it is also possible to describe the allowed designation  with a Regular Expressions.

Each level is also described with a prompt and a help text.

It is possible to have several different formats / prefixes at the same level but for different object categories.

The edit designation dialog is improved so that you can edit the complete designation and the program will automatically verify the designation and add prefixes if needed. You will also get sub-rows for the designation with one row for each level, with prompt and tooltip. When creating new object you will get one extra sub-row for the new object, but it is still possible to create many levels at one time if you have the complete designation by typing it in the designation row.

DesignationFormat

 

In the designation format dialog, you create the named designation formats. The named Designation formats is then used in the new designation configuration dialog to select what designation format to use in the different designation structures.

The settings are stored on the standard and are included in the export / import functionality. You can also export the settings so that you can edit the designations offline in elMaster Design and get the same visual result.

If not you will need to save/update the drawing to get the correct format of the designations on the drawing.

Category Structures

In Master Concept it is possible to specify how your plant should be structured.

In Category settings you can specify that a category is an End Category. That means that no objects are allowed under an object with a category that is specified as an End Category.

Form version 19.0 you can also create named category structures that can be used in different objects designation structures.

In the Category Structure dialog, you create the category structure trees and store them as a named category structure. In the new designation configuration dialog you can specify what category structure should be used for what designation structure. It is also possible to set if it is mandatory to follow the structure or if users should get a warning when trying to create something that does not comply with the specified category structure.

CatStruct

 

Letter Codes

Letter codes are used to create new designations or set object categories for objects with a new designation. New for version 19.0 is that you can specify a filter for the upper designation that limits the number of proposed designations. There is also a new description field that is used if there is more than one available alternative when creating a new objects. The description text is also stored on the created objects Denom1 field.

In version 19.0 it is possible to create designations that are only numbers, [none] is used as letter code for that purpose. Designations without counter, with only letters is also possible to create if you set the length number part to 0.

letterCodes

Product Status

Current Releases

– Master Concept 16.2.5 (Version: 16.2.5.26)
– Master Concept 12.3.10 (Version: 12.3.10.2)
– Master Concept 11.2.6 (Version: 11.2.6.1)
– Master Concept 10.5.7 (Version: 10.5.7.14)

Product Status

Current Releases

– Master Concept 12.3.4 (Version: 12.3.4.3)
– Master Concept 11.2.6 (Version: 11.2.6.1)
– Master Concept 10.5.7 (Version: 10.5.7.14)
– Master Concept 9.5.1 (Version: 9.0.0.275)

Update: Using switches for AutoCAD verticals

When starting elMaster Design the application start will first start the AutoCAD you used last and then load elMaster Design functionality. If there are more AutoCAD products installed you need to make sure the desired product is the one you had last started before starting elMaster Design. Assuming you always want the same version and product there are settings to make switching applications easier.

 

Switches

The following switches are supported both in configuration of Document Start and on shortcuts for stand alone Design.

/product is passed on to AutoCAD and accepts the same input as the native AutoCAD switch. It expects a product shortname like; ACAD, ACADM, MEP

/acadver accepts version as written in the name of the vertical; 2014, 2015, 2016. Version numbers on format R19.1 are currently not supported. Please note that support for this switch was intruduced in 12.2.2.

/p is the native AutoCAD switch for profile. For some starts you may have to refer to an existing profile to get the desired environment. If no profile is specified AutoCAD will be launched and AutoCAD will continue using which ever profile is current.

 

Document start settings in MasterConcept

The configuration of what application to start is found among the document settings; Administration > Settings > Document > Document type. Go to the tab Document Start and look for the columns External Application and Switches.

External Application & Switches

Currently using AutoCAD 2015 while trying out 2016.

The column Switches works very much the same way as adding switches to a program shortcut.

When setting external application to MasterDesign the Design profile is loaded by the document start and there is no need to specify profile.

 

Shortcut for stand alone elMaster Design

The switches above are supported by stand alone elMaster Design by editing the shortcut adding the desired switches.

Shortcut with switches

Shortcut with switches

Product Status

Current Releases

– Master Concept 12.3.3 (Version: 12.3.3.2)
– Master Concept 11.2.6 (Version: 11.2.6.1)
– Master Concept 10.5.7 (Version: 10.5.7.14)
– Master Concept 9.5.1 (Version: 9.0.0.275)

Product Status

Current Releases

– Master Concept 12.2.2 (Version: 12.2.2.29)
– Master Concept 11.2.6 (Version: 11.2.6.1)
– Master Concept 10.5.7 (Version: 10.5.7.14)
– Master Concept 9.5.1 (Version: 9.0.0.275)

Planned Releases

Product Status

Current Releases

– Master Concept 12.2.1 (Version: 12.2.1.20)
– Master Concept 11.2.6 (Version: 11.2.6.1)
– Master Concept 10.5.7 (Version: 10.5.7.14)
– Master Concept 9.5.1 (Version: 9.0.0.275)

Planned Releases

– During Q3 we plan to release a 12.2.2 fix.